Rated voltage of generator set: AC 220V ~ AC 480V

Single rated power of generator set: 90KW ~ 2000KW

Frequency of generator set: 50HZ or 60HZ

Connection mode: Y-type three-phase four-wire

Synchronization phase difference: 1 ° ~ 25 °, generally set at 10 °

Load distribution difference: 5% adjustable

Reverse power action setting: 5% ~ 20% adjustable

Positive power action setting: "ON" 20% ~ 100% adjustable, generally set at 80%, "OFF" 0% ~ 80% adjustable, generally set at 30%.

Classification:

Keywords: Diesel generator | Maintenance diesel generator set

  • Product Description
  • Performance characteristics
    • Commodity name: Mold cabinet
    • Commodity ID: 1214169909676363776

    After the two generators are in parallel, a high-power generator supplies power to the load, which can balance the load and complement each other. According to the size of the load and decided to open a few units (the unit in the rated load of 75% of the operating conditions of the lowest fuel consumption rate), so as to achieve the purpose of saving diesel and reducing the cost of generators.

     

    Performance characteristics

    After the two generators are in parallel, a high-power generator supplies power to the load, which can balance the load and complement each other. According to the size of the load and decided to open a few units (the unit in the rated load of 75% of the operating conditions of the lowest fuel consumption rate), so as to achieve the purpose of saving diesel and reducing the cost of generators.

    Realize uninterruptible power supply and operation exchange between generator sets to ensure the normal production of the factory. When the unit is converted into use, the standby unit can be incorporated into the operation system, and then all the loads can be transferred to the already running standby unit, and then the original operation unit can be stopped. There is no need to cut off power in the middle.

    When the two units operate in parallel, when the load suddenly increases, the current impact is equally shared by the two units. The loads of each unit are mutually complementary and complementary, and the impact resistance is strong, so that the stress of each unit is reduced. Under the condition of large load impact, it can withstand greater impact than that of single unit operation. At the same time, the voltage and frequency are stable, which can extend the working life of the unit.

    With the different power consumption, it is decided to use single machine operation or parallel connection of two machines, so as to avoid the waste of load operation of two machines and the risk of overload operation of single machine.

    The parallel cabinet has the function of power distribution cabinet, so it is not necessary to purchase another power distribution cabinet.

     

    img

     
  • Technical parameters

    Rated voltage of generator set: AC 220V ~ AC 480V

    Single rated power of generator set: 90KW ~ 2000KW

    Frequency of generator set: 50HZ or 60HZ

    Connection mode: Y-type three-phase four-wire

    Synchronization phase difference: 1 ° ~ 25 °, generally set at 10 °

    Load distribution difference: 5% adjustable

    Reverse power action setting: 5% ~ 20% adjustable

    Positive power action setting: "ON" 20% ~ 100% adjustable, generally set at 80%, "OFF" 0% ~ 80% adjustable, generally set at 30%.

Online Inquiry

%{tishi_zhanwei}%

Contact Us

You can contact us in the following ways. We thank you for your attention to us.And look forward to your advice:

Tel: 86(755)-27495168

Mobile: 8618927487489

E-mail: fdk@fudiankang.com

Address: 902, 9th Floor, 107 Guodao Ya Meicheng Building, Longteng Community, xixiang street, Bao 'an District, Shenzhen

Focus on us

Online consultation

Submission

Copyright©2024 All rights reserved of Shenzhen Fudiankang Diesel Generator Co., Ltd.